Stage 01 · Clarify
Before any test: what does the spec not say?
The brief arrives as one paragraph, like in an interview. It becomes numbered requirements only after the questions below.
The brief, as given
v1.0A temperature monitor reads an I2C sensor and sends TEMP <value> over UART once per second. It measures -20 to 85 °C with ±1 °C accuracy. An LED turns on above 80 °C and turns off again with hysteresis. It must work across the 5 V supply tolerance and behave in a defined way outside the measuring range.
How would you test it?
Blocks found while reading: sensor (I2C) → measurement → threshold & LED → UART formatter, with supply across all of them. Each block gives rows to the matrix.
Requirements after review
v1.1| ID | Requirement | Version |
|---|---|---|
| TMP-01 | Accuracy ±1 °C across -20 to 85 °C | v1.0 |
| TMP-02 | One message per second, period 1000 ± 50 ms | v1.1 · Q1 |
| TMP-03 | Format TEMP <integer>, negatives as TEMP -5 | v1.1 · Q7 |
| TMP-04 | LED on above 80 °C, off below 78 °C. At exactly 80 °C the LED stays off. | v1.1 · Q2 Q3 |
| TMP-05 | Works across a 4.75 to 5.25 V supply | v1.1 · Q6 |
| TMP-06 | Outside -20 to 85 °C: send ERR RANGE, no reading | v1.1 · Q5 |
| TMP-07 | Sensor not answering: ERR SENSOR within 2 s, recovers by itself | new · Q4 |
Questions to the spec
Seven questions before the first test, twelve still open.
Q1What does "once per second" allow?TMP-02 → v1.1
Why it matters
A period without a tolerance can never fail, so it cannot be tested.
Assumed answer
1000 ms ± 50 ms between consecutive messages.
Effect on the spec
TMP-02 → v1.1
Q2What is the hysteresis?TMP-04 → v1.1
Why it matters
Without it the LED test has no expected result on the way down.
Assumed answer
The LED turns off below 78 °C.
Effect on the spec
TMP-04 → v1.1
Q3At exactly 80 °C: on or off?TMP-04 clarified
Why it matters
"Above" is ambiguous right at the edge, where bugs live.
Assumed answer
Strictly above: at 80 °C the LED stays off.
Effect on the spec
TMP-04 clarified
Q4What if the sensor stops answering?TMP-07 added
Why it matters
The most common field fault is missing from the spec.
Assumed answer
ERR SENSOR within 2 s, readings resume by themselves.
Effect on the spec
TMP-07 added
Q5What is "defined behaviour" outside the range?TMP-06 → v1.1
Why it matters
An undefined result cannot be checked.
Assumed answer
Send ERR RANGE and never publish the value.
Effect on the spec
TMP-06 → v1.1
Q6Which supply band is "5 V tolerance"?TMP-05 → v1.1
Why it matters
The configuration tests need real numbers.
Assumed answer
4.75 to 5.25 V.
Effect on the spec
TMP-05 → v1.1
Q7How are negative values and resolution sent?TMP-03 → v1.1
Why it matters
The format check must cover the minus sign.
Assumed answer
Whole degrees, TEMP -5.
Effect on the spec
TMP-03 → v1.1
Q8Within how long must readings resume after the sensor answers again?open · TMP-07
Why it matters
"recovers by itself" has no time limit, so it can never fail.
Assumed until answered
Readings resume within 2 s after the sensor answers again, the same limit as the way into ERR SENSOR. TC-TMP07-UPG-01 and TC-TMP07-FI-02 use 2 s.
Effect on the spec
open · TMP-07
Q9Does the LED compare the raw sensor value or the rounded whole number, and is the value rounded or truncated?open · TMP-03 TMP-04
Why it matters
At 80.4 °C the device reports "TEMP 80", so an LED that is on looks like a bug.
Assumed until answered
The LED compares the raw sensor value. The value on the line is rounded half away from zero: 80.5 °C gives TEMP 81, -0.5 °C gives TEMP -1. Python's round() uses banker's rounding (round(80.5) is 80), a known bug source at x.5.
Effect on the spec
open · TMP-03 TMP-04
Q10Are -20 °C and 85 °C inside the valid range?open · TMP-01 TMP-06
Why it matters
The edges are where range bugs live (see B3).
Assumed until answered
-20 °C and 85 °C are inside the valid range: TEMP -20 and TEMP 85 are readings. The range check compares the raw value, the same as the LED, so 85.1 °C and -20.1 °C give ERR RANGE.
Effect on the spec
open · TMP-01 TMP-06
Q11Is the ±50 ms limit per message only, or is there also a long-term limit, such as messages per hour?open · TMP-02
Why it matters
Slow drift can pass every single interval (see B5).
Assumed until answered
The ±50 ms limit applies to each interval only. There is no long-term limit, so TC-TMP02-STR-01 checks every interval over 12 h and nothing more.
Effect on the spec
open · TMP-02
Q12What is the LED state at power-up and during ERR SENSOR or ERR RANGE?open · TMP-04
Why it matters
The fault states have no expected LED result.
Assumed until answered
Fail-safe. During ERR SENSOR the LED is on. During ERR RANGE above 85 °C it is on, below -20 °C it is off. At power-up it is off until the first reading. After an error the hysteresis continues from the LED state shown during the error: on after ERR SENSOR and after ERR RANGE above 85 °C, off after ERR RANGE below -20 °C. There is no memory of the state before the error. No case checks the LED in these states yet (TMP-04 UPG gap).
Effect on the spec
open · TMP-04
Q13During an error, is the ERR message sent every second or only once?open · TMP-02 TMP-06 TMP-07
Why it matters
The timing tests need to know which messages count.
Assumed until answered
While an error lasts, one ERR message replaces each reading, every period. Until the answer, cards accept one ERR or one per period, and the period during an error is not checked (TMP-02 FI gap).
Effect on the spec
open · TMP-02 TMP-06 TMP-07
Q14Which line ending and UART settings are used, and is -0.4 °C sent as "TEMP 0" or "TEMP -0"?open · TMP-03
Why it matters
The format check needs exact bytes.
Assumed until answered
115200 baud, 8N1, each line ends with LF. -0.4 °C is sent as TEMP 0, -0.5 °C as TEMP -1, never TEMP -0. The simulator has no baud rate; the real lab uses these settings.
Effect on the spec
open · TMP-03
Q15What must happen outside 4.75 to 5.25 V?open · TMP-05
Why it matters
A brown-out must never produce a wrong reading.
Assumed until answered
Outside 4.75 to 5.25 V the device may go silent or send an ERR line, but never a wrong reading or a corrupt line. Above 5.25 V the device is silent with the LED off. After the supply returns it sends its first reading within 2 s.
Effect on the spec
open · TMP-05
Q16How fast must the LED react after the threshold is crossed?open · TMP-04
Why it matters
A card expects "within 1.5 s", but no requirement says so.
Assumed until answered
The LED follows a threshold crossing within 1.5 s, the value of the design's model card.
Effect on the spec
open · TMP-04
Q17Does the device expose diagnostics such as error counters or logs?open · TMP-06 TMP-07
Why it matters
The OBS cards need a source.
Assumed until answered
The device has no diagnostics beyond its UART lines and the LED. The OBS cards check the error lines only.
Effect on the spec
open · TMP-06 TMP-07
Q18Does the device read anything on UART RX?open · TMP-03
Why it matters
SEC is not applicable for the bench only if there is no input path.
Assumed until answered
The device reads nothing on UART RX. With no input path, SEC is not applicable for the bench.
Effect on the spec
open · TMP-03
Q19Must one failed sensor read trigger ERR SENSOR, or only a failure that lasts longer?open · TMP-07
Why it matters
One bus glitch would raise a false alarm.
Assumed until answered
The first failed sensor read triggers ERR SENSOR. A single bus glitch therefore gives one ERR SENSOR line.
Effect on the spec
open · TMP-07
In a real project these go to the system engineer. Here the answers are assumptions, written into the STP under Assumptions.