TC-TMP01-FUN-01
P1 · automated
25 °C reads 24 to 26
- Class
- FUN · functional
- Technique
- Equivalence class: one value inside the range
- Level
- smoke
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · temperature 25 °C
- Steps
- Set the sensor to 25 °C
- Expected
TEMP 24, TEMP 25 or TEMP 26 (±1 °C)
- Pass criteria
- The second message after the change is within ±1 °C of 25 °C
Matrix: TMP-01 × FUN · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp01.py::test_tc_tmp01_fun_01
@tc("TC-TMP01-FUN-01")
@pytest.mark.smoke
def test_tc_tmp01_fun_01(dut: TempMonitor, case: Case) -> None:
"""One value inside the range reads within the TMP-01 accuracy of the set value."""
tmp01_fun_01(dut, case)
TC-TMP01-BND-01
P1 · automated
Accuracy at the -20 °C edge
- Class
- BND · boundary
- Technique
- Boundary values on the lower range edge
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- lower edge: -19.9 · -20.0 · -20.1 °C
- Steps
- Set the sensor to -19.9 °C
- Set -20.0 °C
- Set -20.1 °C
- Expected
- A reading within ±1 °C of the set value (TMP-01). Q9 assumed: -19.9 °C reads as
TEMP -20. - A reading within ±1 °C of the set value (TMP-01). Q9 assumed: -20.0 °C reads as
TEMP -20. Q10 assumed: -20.0 °C is inside the range. ERR RANGE, no TEMP message (TMP-06, Q10 assumed: the range check compares the raw value)
- Pass criteria
- All three steps
Matrix: TMP-01 × BND · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp01.py::test_tc_tmp01_bnd_01
@tc("TC-TMP01-BND-01")
@pytest.mark.regression
@each("lower edge")
def test_tc_tmp01_bnd_01(dut: TempMonitor, case: Case) -> None:
"""Accuracy at the lower range edge, one point per test.
Questions: Q9 and Q10 assumed (stp.yaml).
"""
check_range_point(dut, case, exact=False)
TC-TMP01-BND-02
P1 · automated
Accuracy at the 85 °C edge
- Class
- BND · boundary
- Technique
- Boundary values on the upper range edge
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- upper edge: 84.9 · 85.0 · 85.1 °C
- Steps
- Set the sensor to 84.9 °C
- Set 85.0 °C
- Set 85.1 °C
- Expected
- A reading within ±1 °C of the set value (TMP-01). Q9 assumed: 84.9 °C reads as
TEMP 85. - A reading within ±1 °C of the set value (TMP-01). Q9 assumed: 85.0 °C reads as
TEMP 85. Q10 assumed: 85.0 °C is inside the range. ERR RANGE, no TEMP message (TMP-06, Q10 assumed: the range check compares the raw value)
- Pass criteria
- All three steps
Matrix: TMP-01 × BND · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp01.py::test_tc_tmp01_bnd_02
@tc("TC-TMP01-BND-02")
@pytest.mark.regression
@each("upper edge")
def test_tc_tmp01_bnd_02(dut: TempMonitor, case: Case) -> None:
"""Accuracy at the upper range edge, one point per test.
Questions: Q9 and Q10 assumed (stp.yaml).
"""
check_range_point(dut, case, exact=False)
TC-TMP01-PRF-01
P2 · automated
Linearity sweep, 5 points
- Class
- PRF · performance
- Technique
- Sweep across the range against the set value
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · sweep cold 0 °C · sweep room 25 °C · sweep warm 50 °C
- Points
- sweep edges: -20 · 85 °C
- Steps
- For each point, edges and test conditions, set the sensor
- Expected
- A reading within ±1 °C of each set value (TMP-01). The points read as
TEMP -20, TEMP 0, TEMP 25, TEMP 50 and TEMP 85.
- Pass criteria
- All 5 points within ±1 °C
Matrix: TMP-01 × PRF · Last result: PASSED 5 / 5
Code: benches/bench1_temp/tests/test_tmp01.py::test_tc_tmp01_prf_01
@tc("TC-TMP01-PRF-01")
@pytest.mark.regression
@each("sweep edges", "sweep cold", "sweep room", "sweep warm")
def test_tc_tmp01_prf_01(dut: TempMonitor, case: Case) -> None:
"""Linearity sweep: the range edges and the sweep test conditions, one point per test.
Questions: Q10 assumed (stp.yaml).
"""
point = case.input
stream_running(dut)
dut.set_temperature(float(point.value))
check_accuracy(point.value, settle(dut)[-1], dut.params.accuracy_c)
TC-TMP01-STR-01
P2 · automated
12 h at 25 °C, error stays within ±1 °C
- Class
- STR · stress and soak
- Technique
- Soak at a constant temperature
- Level
- soak
- Precondition
- UART stream running, virtual clock
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · soak duration 12 h
- Steps
- Hold the sensor at 25 °C for 12 h of device time, record every message
- Expected
- Every reading is
TEMP 24, TEMP 25 or TEMP 26 for 12 h
- Pass criteria
- No reading outside ±1 °C, no ERR message during the run
Matrix: TMP-01 × STR · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp01.py::test_tc_tmp01_str_01
@tc("TC-TMP01-STR-01")
@pytest.mark.soak
def test_tc_tmp01_str_01(dut: TempMonitor, case: Case) -> None:
"""Soak at the start temperature on the virtual clock: every reading within the accuracy."""
stream_running(dut)
celsius = start_temperature(dut, case)
soak = case.condition("soak duration")
dut.wait_ms(case.ms("soak duration"))
received = dut.read_received()
accuracy = dut.params.accuracy_c
assert received, f"During the {soak.value} {soak.unit} soak the device sent nothing."
errors = [m for m in received if m.kind in (MessageKind.ERR_RANGE, MessageKind.ERR_SENSOR)]
assert not errors, (
f"During the {soak.value} {soak.unit} soak at {celsius} °C the device sent {len(errors)} "
f"ERR lines, first {describe(errors[:1])}. Expected no ERR message."
)
wrong = [
m
for m in received
if m.kind is MessageKind.READING
and m.value is not None
and abs(m.value - celsius) > accuracy
]
assert not wrong, (
f"During the {soak.value} {soak.unit} soak at {celsius} °C, {len(wrong)} of "
f"{len(received)} readings were outside ±{accuracy:g} °C, first {describe(wrong[:1])}. "
f"Expected every reading within ±{accuracy:g} °C of {celsius} °C (TMP-01)."
)
TC-TMP02-FUN-01
P1 · automated
60 consecutive messages, none missing
- Class
- FUN · functional
- Technique
- Count messages over a fixed window
- Level
- smoke
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · window 60 messages
- Points
- period limits: 950 · 1050 ms
- Steps
- Start the window at a message, count 60 messages
- Expected
- 60 messages, each 950 to 1050 ms after the one before, so none is missing
- Pass criteria
- 60 messages, no gap longer than 1050 ms
Matrix: TMP-02 × FUN · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp02.py::test_tc_tmp02_fun_01
@tc("TC-TMP02-FUN-01")
@pytest.mark.smoke
def test_tc_tmp02_fun_01(dut: TempMonitor, case: Case) -> None:
"""A window of consecutive messages, none missing."""
tmp02_fun_01(dut, case)
TC-TMP02-PRF-01
P1 · automated
Period 1000 ± 50 ms over 300 messages
- Class
- PRF · performance
- Technique
- Timestamp consecutive messages
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · window 300 messages
- Points
- period limits: 950 · 1050 ms
- Steps
- Timestamp 300 consecutive messages
- Expected
- Each of the 299 intervals is 950 to 1050 ms
- Pass criteria
- No interval outside 950 to 1050 ms
Matrix: TMP-02 × PRF · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp02.py::test_tc_tmp02_prf_01
@tc("TC-TMP02-PRF-01")
@pytest.mark.regression
def test_tc_tmp02_prf_01(dut: TempMonitor, case: Case) -> None:
"""Every interval of a long window within the period limits."""
check_intervals(case, message_window(dut, case))
TC-TMP02-STR-01
P3 · automated
Period stable over 12 h
- Class
- STR · stress and soak
- Technique
- Soak with a histogram of periods
- Level
- soak
- Precondition
- UART stream running, virtual clock
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · soak duration 12 h
- Points
- period limits: 950 · 1050 ms
- Steps
- Run 12 h of device time, timestamp every message, store the histogram
- Expected
- Every interval is 950 to 1050 ms for 12 h (Q11 open: no long-term limit checked)
- Pass criteria
- No interval outside 950 to 1050 ms, histogram attached to the result
Matrix: TMP-02 × STR · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp02.py::test_tc_tmp02_str_01
@tc("TC-TMP02-STR-01")
@pytest.mark.soak
def test_tc_tmp02_str_01(
dut: TempMonitor, case: Case, record_property: Callable[[str, object], None]
) -> None:
"""Soak on the virtual clock: every interval within the period limits, histogram attached.
Questions: Q11 assumed (stp.yaml), so no long-term limit is checked.
"""
first = stream_running(dut)
soak = case.condition("soak duration")
dut.wait_ms(case.ms("soak duration"))
messages = [first, *dut.read_received()]
histogram = Counter(b.t_ms - a.t_ms for a, b in pairwise(messages))
record_property("period_histogram_ms", {str(ms): histogram[ms] for ms in sorted(histogram)})
check_intervals(case, messages)
low, high = case.limits_ms("period limits")
silent = dut.now_ms() - messages[-1].t_ms
assert silent <= high, (
f"The last message of the {soak.value} {soak.unit} soak was {messages[-1]}, "
f"{silent} ms before its end. Expected a message every {low} to {high} ms (TMP-02)."
)
TC-TMP03-FUN-01
P1 · automated
Format TEMP <integer> on all messages
- Class
- FUN · functional
- Technique
- A regex runs on every message of every test
- Level
- smoke
- Precondition
- Any case of the run, UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Inputs from
- Every message of every case in the run
- Steps
- Match every received line against the format
- Expected
- Every line is
TEMP <integer>, ERR RANGE or ERR SENSOR, ends with LF, has no decimal point and is never TEMP -0 (Q14 assumed)
- Pass criteria
- No line fails the match
Matrix: TMP-03 × FUN · Last result: PASSED 61 / 61
Code: benches/bench1_temp/tests/test_tmp03.py::test_tc_tmp03_fun_01
@tc("TC-TMP03-FUN-01")
@pytest.mark.smoke
def test_tc_tmp03_fun_01(dut: TempMonitor, case: Case) -> None:
"""The format of every line: here on the stream of this case, and on every other case.
The card's points are every message of every case in the run. The
conftest runs the same check after every other bench test and records
it as a result of this card, `<host nodeid>::TC-TMP03-FUN-01` (ADR-022).
This test checks the stream from the reset through the settle window at
the start temperature.
Questions: Q14 assumed (stp.yaml): LF ending, never `TEMP -0`.
"""
tmp03_fun_01(dut, case)
TC-TMP03-BND-01
P2 · automated
Rounding at the half degree, never TEMP -0
- Class
- BND · boundary
- Technique
- Boundary values on the rounding edges
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- half degree: 80.4 · 80.5 · 80.6 °C · half degree below zero: -0.6 · -0.5 · -0.4 °C
- Steps
- Set the sensor to 80.4 °C, then 80.5 °C, then 80.6 °C
- Set the sensor to -0.6 °C, then -0.5 °C, then -0.4 °C
- Expected
TEMP 80, TEMP 81, TEMP 81 (Q9 assumed: half away from zero)TEMP -1, TEMP -1, TEMP 0, and no TEMP -0 (Q9 and Q14 assumed)
- Pass criteria
- All six messages match exactly, no
TEMP -0 during the run
Matrix: TMP-03 × BND · Last result: PASSED 6 / 6
Code: benches/bench1_temp/tests/test_tmp03.py::test_tc_tmp03_bnd_01
@tc("TC-TMP03-BND-01")
@pytest.mark.regression
@each("half degree", "half degree below zero")
def test_tc_tmp03_bnd_01(dut: TempMonitor, case: Case) -> None:
"""Rounding at the half degree, one point per test, never `TEMP -0`.
Questions: Q9 and Q14 assumed (stp.yaml): half away from zero, -0.4 °C is `TEMP 0`.
"""
point = case.input
stream_running(dut)
dut.set_temperature(float(point.value))
last = settle(dut)[-1]
want = reading_text(reading(point.value))
assert last.kind is MessageKind.READING and last.text == want, (
f"After setting {point} the second message was {last}. "
f"Expected exactly `{want}` (Q9 assumed: rounded half away from zero)."
)
check_format(dut, "received in this case, so no `TEMP -0`,")
TC-TMP03-CPL-01
P2 · automated
Negative values sent as TEMP -5
- Class
- CPL · compliance
- Technique
- Clause check against the spec text
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · negative example -5 °C · zero 0 °C
- Points
- lower edge: -20 °C
- Steps
- Set the sensor to -20 °C
- Set -5 °C
- Set 0 °C
- Expected
TEMP -20 (Q10 assumed: -20 °C is inside the range)TEMP -5TEMP 0
- Pass criteria
- All three messages match exactly
Matrix: TMP-03 × CPL · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp03.py::test_tc_tmp03_cpl_01
@tc("TC-TMP03-CPL-01")
@pytest.mark.regression
@each("lower edge", "negative example", "zero")
def test_tc_tmp03_cpl_01(dut: TempMonitor, case: Case) -> None:
"""Negative values on the line as the spec text writes them, one value per test.
Questions: Q10 assumed (stp.yaml): the lower edge is inside the range.
"""
point = case.input
stream_running(dut)
dut.set_temperature(float(point.value))
last = settle(dut)[-1]
want = reading_text(reading(point.value))
assert last.text == want, (
f"After setting {point} the second message was {last}. Expected exactly `{want}` (TMP-03)."
)
TC-TMP04-FUN-01
P1 · automated
LED on at 82 °C, off at 25 °C
- Class
- FUN · functional
- Technique
- One value above the threshold inside the range, one far below
- Level
- smoke
- Precondition
- LED off, UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · high temperature 82 °C
- Steps
- Set the sensor to 82 °C
- Set 25 °C
- Expected
TEMP 82, LED on within 1.5 s (Q16 assumed)TEMP 25, LED off within 1.5 s (Q16 assumed)
- Pass criteria
- Both steps, no ERR message during the run
Matrix: TMP-04 × FUN · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp04.py::test_tc_tmp04_fun_01
@tc("TC-TMP04-FUN-01")
@pytest.mark.smoke
def test_tc_tmp04_fun_01(dut: TempMonitor, case: Case) -> None:
"""LED on at a value above the threshold inside the range, off again far below.
Questions: Q16 assumed (stp.yaml): the LED follows within 1.5 s.
"""
tmp04_fun_01(dut, case)
TC-TMP04-NEG-01
P1 · automated
No flicker under 79 ↔ 81 oscillation
- Class
- NEG · negative
- Technique
- Error guessing: oscillate the input around the threshold
- Level
- regression
- Precondition
- LED off, UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · oscillation low 79 °C · oscillation high 81 °C · toggle every 200 ms · window 60 messages
- Steps
- Toggle the sensor between 79 °C and 81 °C every 200 ms for 60 messages
- Expected
- LED off until the first
TEMP 81, then on for the rest of the run (79 °C is not below 78 °C)
- Pass criteria
- The LED changes state at most once in 60 messages
Matrix: TMP-04 × NEG · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp04.py::test_tc_tmp04_neg_01
@tc("TC-TMP04-NEG-01")
@pytest.mark.regression
def test_tc_tmp04_neg_01(dut: TempMonitor, case: Case) -> None:
"""No flicker while the input oscillates around the threshold, inside the hysteresis.
The LED is read at every time step of the simulator resolution, so no
change can hide between two reads.
"""
stream_running(dut)
led_off(dut)
low, high = case.value("oscillation low"), case.value("oscillation high")
toggle_ms = case.ms("toggle every")
size = int(case.value("window"))
res = case.resolution("time")
step_ms = to_ms(res.step, res.unit)
start = dut.now_ms()
# TMP-02: every message comes within max_interval_ms, so the window is
# over by this time. A device that falls silent fails here, it can't hang.
deadline = start + size * dut.max_interval_ms
samples: list[tuple[int, bool]] = [(start, dut.led_on())]
received: list[Message] = []
go_high = False
while len(received) < size and dut.now_ms() < deadline:
dut.set_temperature(float(high if go_high else low))
go_high = not go_high
for _ in range(toggle_ms // step_ms):
dut.wait_ms(step_ms)
samples.append((dut.now_ms(), dut.led_on()))
received += dut.read_received()
assert len(received) >= size, (
f"Only {len(received)} messages came in {dut.now_ms() - start} ms of oscillation. "
f"Expected {size} messages, one every period (TMP-02)."
)
end = received[size - 1].t_ms
seen = [(t, on) for t, on in samples if t <= end]
changes = [t for (_, a), (t, b) in pairwise(seen) if a is not b]
assert len(changes) <= 1, (
f"The LED changed state {len(changes)} times in {size} messages, at "
f"{', '.join(f'{t} ms' for t in changes[:5])}. Expected at most once: {low} °C is "
f"not below {dut.params.led_off_c:g} °C (TMP-04)."
)
high_text = reading_text(reading(high))
first_high = next((m.t_ms for m in received[:size] if m.text == high_text), None)
wrong = [(t, on) for t, on in seen if (first_high is None or t < first_high) is on]
assert not wrong, (
f"The LED was {state(wrong[0][1])} at {wrong[0][0]} ms. Expected it off until the first "
f"`{high_text}`"
+ (f" at {first_high} ms, then on for the rest of the run." if first_high else ".")
)
TC-TMP04-BND-01
P1 · automated
Rising edge: LED off at 80.0 °C, on at 80.1 °C
- Class
- BND · boundary
- Technique
- Boundary values + state transition
- Level
- regression
- Precondition
- LED off, UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- rising: 79.9 · 80.0 · 80.1 °C
- Steps
- Set the sensor to 79.9 °C
- Set 80.0 °C
- Set 80.1 °C
- Expected
TEMP 80, LED offTEMP 80, LED offTEMP 80, LED on within 1.5 s (Q9 assumed: the LED compares the raw value, Q16 assumed)
- Pass criteria
- All three steps, no ERR message during the run
Matrix: TMP-04 × BND · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp04.py::test_tc_tmp04_bnd_01
@tc("TC-TMP04-BND-01")
@pytest.mark.regression
@each("rising")
def test_tc_tmp04_bnd_01(dut: TempMonitor, case: Case) -> None:
"""Rising edge: the LED stays off at the threshold and turns on one step above it.
Questions: Q9 assumed (the LED compares the raw value) and Q16 assumed
(the LED follows within 1.5 s), stp.yaml.
"""
point = case.input
stream_running(dut)
led_off(dut)
on = point.value > dut.params.led_on_c # TMP-04: on above the threshold, raw value (Q9)
check_led_step(dut, point.value, on, wait=on)
check_no_errors(dut)
TC-TMP04-BND-02
P1 · automated
Falling edge: LED on at 78.0 °C, off at 77.9 °C
- Class
- BND · boundary
- Technique
- Boundary values + state transition
- Level
- regression
- Precondition
- LED on, UART stream running
- Test conditions
- supply 5.0 V · settle window 2 messages · start temperature 81 °C
- Points
- falling: 78.1 · 78.0 · 77.9 °C
- Steps
- Set the sensor to 78.1 °C
- Set 78.0 °C
- Set 77.9 °C
- Expected
TEMP 78, LED onTEMP 78, LED onTEMP 78, LED off within 1.5 s (Q9 assumed: the LED compares the raw value, Q16 assumed)
- Pass criteria
- All three steps, no ERR message during the run
Matrix: TMP-04 × BND · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp04.py::test_tc_tmp04_bnd_02
@tc("TC-TMP04-BND-02")
@pytest.mark.regression
@each("falling")
def test_tc_tmp04_bnd_02(dut: TempMonitor, case: Case) -> None:
"""Falling edge: the LED stays on at the off threshold and turns off one step below it.
Questions: Q9 assumed (the LED compares the raw value) and Q16 assumed
(the LED follows within 1.5 s), stp.yaml.
"""
point = case.input
stream_running(dut)
with precondition("LED on"):
start_temperature(dut, case)
dut.wait_led(True)
off = point.value < dut.params.led_off_c # TMP-04: off below the threshold, raw value (Q9)
check_led_step(dut, point.value, not off, wait=off)
check_no_errors(dut)
TC-TMP05-BND-01
P2 · automated
Outside the band: no corrupt UART output
- Class
- BND · boundary
- Technique
- Boundary values on voltage
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- low edge: 4.8 · 4.75 · 4.7 V · high edge: 5.2 · 5.25 · 5.3 V
- Steps
- Set the supply to 4.80 V, then 4.75 V
- Set the supply to 4.70 V
- Set the supply to 5.20 V, then 5.25 V
- Set the supply to 5.30 V
- Expected
TEMP 25 at 4.80 V and 4.75 V- No wrong reading at 4.70 V: any
TEMP message is within ±1 °C of the 25 °C start temperature (TMP-01), every line passes TC-TMP03-FUN-01 (Q15 assumed: silence or an ERR line accepted) TEMP 25 at 5.20 V and 5.25 V- No wrong reading at 5.30 V: any
TEMP message is within ±1 °C of the 25 °C start temperature (TMP-01), every line passes TC-TMP03-FUN-01 (Q15 assumed: silence or an ERR line accepted)
- Pass criteria
- All four steps
Matrix: TMP-05 × BND · Last result: PASSED 6 / 6
Code: benches/bench1_temp/tests/test_tmp05.py::test_tc_tmp05_bnd_01
@tc("TC-TMP05-BND-01")
@pytest.mark.regression
@requires(POWER_CONTROL)
@each("low edge", "high edge")
def test_tc_tmp05_bnd_01(dut: TempMonitor, case: Case) -> None:
"""Supply at the band edges and one step outside, one point per test.
Inside the band the reading is the start temperature. Outside it any
line is allowed but a wrong reading or a corrupt line.
Questions: Q15 assumed (stp.yaml): silence or an ERR line outside the band.
"""
point = case.input
stream_running(dut)
dut.set_supply(float(point.value))
p = dut.params
if p.supply_min_v <= point.value <= p.supply_max_v:
last = settle(dut)[-1]
want = reading_text(int(case.value("start temperature")))
assert last.text == want, (
f"At {point} the second message was {last}. Expected exactly `{want}` (TMP-05)."
)
return
# Q15 assumed: silence is allowed, so read for as long as the settle
# window lasts at most (TMP-02), and judge every line that came.
seen: list[Message] = []
end = dut.now_ms() + p.conditions.settle_messages * dut.max_interval_ms
while (left := end - dut.now_ms()) > 0 and (message := dut.read_message(left)) is not None:
seen.append(message)
wrong = wrong_readings(dut, case, seen)
assert not wrong, (
f"At {point} the device sent {describe(wrong)}. Expected no wrong reading: any `TEMP` "
f"message within ±{p.accuracy_c:g} °C of {case.value('start temperature')} °C "
f"(TMP-01, Q15)."
)
check_format(dut, f"received at {point}")
TC-TMP05-CFG-01
P2 · automated
Smoke set at three supply levels
- Class
- CFG · configuration
- Technique
- Run the smoke set at each supply level
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- supply band edges: 4.75 · 5.25 V
- Steps
- For each band edge and the nominal supply, run every smoke-level case of this STD
- Expected
- Every smoke case passes at 4.75 V, 5.00 V and 5.25 V
- Pass criteria
- All smoke cases pass at all three levels
Matrix: TMP-05 × CFG · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp05.py::test_tc_tmp05_cfg_01
@tc("TC-TMP05-CFG-01")
@pytest.mark.regression
@requires(POWER_CONTROL)
@each("supply band edges", "supply")
def test_tc_tmp05_cfg_01(dut: TempMonitor, case: Case) -> None:
"""The smoke set at one supply level per test: both band edges and the nominal supply.
The smoke set is every card of level smoke in std.yaml. Each runs its
registered steps from a reset at this supply level, then the format of
its lines is checked (ADR-022).
"""
level = case.input
cards = [c for c in case.std.cases if c.level == "smoke" and c.automation == "automated"]
failures: list[str] = []
for card in cards:
steps = SMOKE_STEPS.get(card.id)
if steps is None:
raise ConfigError(f"{card.id} is a smoke card with no @smoke_steps in steps.py")
dut.reset()
dut.set_supply(float(level.value))
try:
steps(dut, Case(case.std, card))
check_format(dut, f"received in {card.id}")
except AssertionError as exc:
failures.append(f"{card.id}: {exc}")
assert not failures, (
f"At {level}, {len(failures)} of {len(cards)} smoke cases failed. Expected every "
f"smoke case to pass. " + " | ".join(failures)
)
TC-TMP05-FI-01
P2 · automated
Brownout: clean restart, first message within 2 s
- Class
- FI · fault injection and power loss
- Technique
- Fault injection: short supply dip
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · dip level 4.2 V · dip length 50 ms
- Steps
- Drop the supply to 4.2 V for 50 ms, then back to 5.00 V
- Expected
- No corrupt line and no wrong reading, first
TEMP 25 within 2 s after the supply returns (Q15 assumed)
- Pass criteria
- Every line passes TC-TMP03-FUN-01, readings resume within 2 s
Matrix: TMP-05 × FI · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp05.py::test_tc_tmp05_fi_01
@tc("TC-TMP05-FI-01")
@pytest.mark.regression
@requires(POWER_CONTROL)
def test_tc_tmp05_fi_01(dut: TempMonitor, case: Case) -> None:
"""Brownout: a short dip, then a clean restart with the first reading in time.
Questions: Q15 assumed (stp.yaml): first reading within 2 s after the supply returns.
"""
stream_running(dut)
dip = dut.now_ms()
dut.set_supply(float(case.value("dip level")))
dut.wait_ms(case.ms("dip length"))
dut.set_supply(float(case.value("supply")))
returned = dut.now_ms()
limit = dut.timeouts.first_reading_ms
first = dut.wait_message(
MessageKind.READING,
within_ms=limit,
reason=f"Q15 assumed: first reading within {limit} ms after the supply returns",
)
want = reading_text(int(case.value("start temperature")))
assert first.text == want, (
f"The first reading after the supply returned at {returned} ms was {first}. "
f"Expected exactly `{want}`."
)
wrong = wrong_readings(dut, case, [m for m in dut.messages if m.t_ms > dip])
assert not wrong, (
f"After the dip the device sent {describe(wrong)}. Expected no wrong reading (TMP-01)."
)
check_format(dut, "received around the dip")
TC-TMP06-NEG-01
P1 · automated
120 °C → ERR RANGE
- Class
- NEG · negative
- Technique
- Equivalence class outside the range
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · out-of-range temperature 120 °C
- Steps
- Set the sensor to 120 °C
- Expected
ERR RANGE within 2 messages, no TEMP message while at 120 °C (Q13 open: one ERR RANGE or one per message both accepted)
- Pass criteria
- At least one
ERR RANGE, no TEMP 120 or any other TEMP message
Matrix: TMP-06 × NEG · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp06.py::test_tc_tmp06_neg_01
@tc("TC-TMP06-NEG-01")
@pytest.mark.regression
def test_tc_tmp06_neg_01(dut: TempMonitor, case: Case) -> None:
"""Far outside the range: `ERR RANGE` and never a reading.
Questions: Q13 open (stp.yaml): one `ERR RANGE` or one per message both pass.
"""
stream_running(dut)
where = out_of_range(dut, case)
window = error_window(dut)
assert of_kind(window, MessageKind.ERR_RANGE), (
f"After setting {where} the device sent {describe(window)}. "
f"Expected `ERR RANGE` within {dut.params.conditions.settle_messages} messages (TMP-06)."
)
readings = of_kind(window, MessageKind.READING)
assert not readings, (
f"At {where} the device sent {describe(readings)}. Expected no `TEMP` message (TMP-06)."
)
TC-TMP06-BND-01
P1 · automated
85.1 °C → ERR RANGE
- Class
- BND · boundary
- Technique
- Boundary values on the upper range edge
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- upper edge: 84.9 · 85.0 · 85.1 °C
- Steps
- Set the sensor to 84.9 °C
- Set 85.0 °C
- Set 85.1 °C
- Expected
TEMP 85 (Q9 assumed: 84.9 °C rounds to 85)TEMP 85 (Q10 assumed: 85.0 °C is inside the range)ERR RANGE, no TEMP message (Q10 assumed: the range check compares the raw value)
- Pass criteria
- All three steps
Matrix: TMP-06 × BND · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp06.py::test_tc_tmp06_bnd_01
@tc("TC-TMP06-BND-01")
@pytest.mark.regression
@each("upper edge")
def test_tc_tmp06_bnd_01(dut: TempMonitor, case: Case) -> None:
"""Upper range edge, one point per test: readings up to the edge, `ERR RANGE` one step above.
Questions: Q9 and Q10 assumed (stp.yaml).
"""
check_range_point(dut, case, exact=True)
TC-TMP06-BND-02
P1 · automated
-20.1 °C → ERR RANGE
- Class
- BND · boundary
- Technique
- Boundary values on the lower range edge
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- lower edge: -19.9 · -20.0 · -20.1 °C
- Steps
- Set the sensor to -19.9 °C
- Set -20.0 °C
- Set -20.1 °C
- Expected
TEMP -20 (Q9 assumed: -19.9 °C rounds to -20)TEMP -20 (Q10 assumed: -20.0 °C is inside the range)ERR RANGE, no TEMP message (Q10 assumed: the range check compares the raw value)
- Pass criteria
- All three steps
Matrix: TMP-06 × BND · Last result: PASSED 3 / 3
Code: benches/bench1_temp/tests/test_tmp06.py::test_tc_tmp06_bnd_02
@tc("TC-TMP06-BND-02")
@pytest.mark.regression
@each("lower edge")
def test_tc_tmp06_bnd_02(dut: TempMonitor, case: Case) -> None:
"""Lower range edge, one point per test: readings down to the edge, `ERR RANGE` one step below.
Questions: Q9 and Q10 assumed (stp.yaml).
"""
check_range_point(dut, case, exact=True)
TC-TMP06-UPG-01
P1 · automated
Back in range: the first message is a reading within 1000 ± 50 ms
- Class
- UPG · upgrade and recovery
- Technique
- State transition
ERR RANGE to reading
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · out-of-range temperature 120 °C · return after the last error line 1 ms
- Points
- period limits: 950 · 1050 ms
- Steps
- Set the sensor to 120 °C
- 1 ms after the next
ERR RANGE, set 25 °C (the start temperature)
- Expected
ERR RANGE within 2 messages- The next message is
TEMP 25, 950 to 1050 ms after that ERR RANGE (TMP-02: 1000 ± 50 ms)
- Pass criteria
- The first message after the return is a reading on time, and no
ERR RANGE follows it
Matrix: TMP-06 × UPG · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp06.py::test_tc_tmp06_upg_01
@tc("TC-TMP06-UPG-01")
@pytest.mark.regression
def test_tc_tmp06_upg_01(dut: TempMonitor, case: Case) -> None:
"""Back in range: the first message after the return is a reading, on the TMP-02 period.
Questions: Q13 open (stp.yaml): one `ERR RANGE` or one per message both pass.
"""
stream_running(dut)
changed = dut.now_ms()
where = out_of_range(dut, case)
count = dut.params.conditions.settle_messages
err = dut.wait_message(
MessageKind.ERR_RANGE,
within_ms=count * dut.max_interval_ms,
reason=f"TMP-06: `ERR RANGE` within the settle window, {count} messages of at most "
f"{dut.max_interval_ms} ms each (TMP-02)",
)
before = since(dut, changed, err)
assert len(before) <= count, (
f"After setting {where} the device sent {describe(before)}. "
f"Expected `ERR RANGE` within {count} messages (TMP-06)."
)
# The step: 1 ms after that `ERR RANGE`, back to the start temperature.
dut.wait_ms(err.t_ms + case.ms("return after the last error line") - dut.now_ms())
celsius = case.value("start temperature")
dut.set_temperature(float(celsius))
first = dut.next_message()
low, high = case.limits_ms("period limits")
want = reading_text(int(celsius))
assert first.text == want and low <= first.t_ms - err.t_ms <= high, (
f"After the return to {celsius} °C the first message was {first}, "
f"{first.t_ms - err.t_ms} ms after {err}. Expected `{want}` {low} to {high} ms after "
f"that `ERR RANGE` (TMP-02)."
)
after = dut.next_message()
assert after.kind is not MessageKind.ERR_RANGE, (
f"After {first} the device sent {after}. Expected no `ERR RANGE` once back in range."
)
TC-TMP06-OBS-01
P3 · automated
Range error names its cause on the UART
- Class
- OBS · observability
- Technique
- Error line on the UART
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · out-of-range temperature 120 °C
- Steps
- Set the sensor to 120 °C
- Expected
ERR RANGE within 2 messages and no ERR SENSOR, so the line tells a range error from a sensor fault (Q17 assumed: no other diagnostics)
- Pass criteria
- The error line names the injected cause
Matrix: TMP-06 × OBS · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp06.py::test_tc_tmp06_obs_01
@tc("TC-TMP06-OBS-01")
@pytest.mark.regression
def test_tc_tmp06_obs_01(dut: TempMonitor, case: Case) -> None:
"""A range error names its cause: `ERR RANGE`, not `ERR SENSOR`.
Questions: Q17 assumed (stp.yaml): no diagnostics beyond the UART lines and the LED.
"""
stream_running(dut)
where = out_of_range(dut, case)
window = error_window(dut)
assert of_kind(window, MessageKind.ERR_RANGE) and not of_kind(window, MessageKind.ERR_SENSOR), (
f"After setting {where} the device sent {describe(window)}. Expected `ERR RANGE` "
f"within {dut.params.conditions.settle_messages} messages and no `ERR SENSOR`."
)
TC-TMP07-NEG-01
P1 · automated
NACK on read: no stale value sent
- Class
- NEG · negative
- Technique
- Error guessing from field experience
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · last good reading 25 °C
- Steps
- Wait for
TEMP 25, then make the sensor NACK every read
- Expected
- No
TEMP 25 (the last good value) and no other TEMP message after the first NACK
- Pass criteria
- No
TEMP message while the sensor NACKs
Matrix: TMP-07 × NEG · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp07.py::test_tc_tmp07_neg_01
@tc("TC-TMP07-NEG-01")
@pytest.mark.regression
@requires(Fault.I2C_NACK)
def test_tc_tmp07_neg_01(dut: TempMonitor, case: Case) -> None:
"""A NACK on read leaves no stale value on the line."""
good = last_good_reading(dut, case)
dut.inject_fault(Fault.I2C_NACK)
onset = dut.now_ms()
window = error_window(dut)
readings = of_kind(window, MessageKind.READING)
assert not readings, (
f"While the sensor NACKed every read from {onset} ms, the device sent "
f"{describe(readings)}. Expected no `TEMP` message, not even {good.text!r}, the last "
f"good value."
)
TC-TMP07-PRF-01
P1 · automated
ERR SENSOR latency within 2 s over repeated NACK faults
- Class
- PRF · performance
- Technique
- Inject NACK faults at known moments, measure the time to
ERR SENSOR
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · early fault onset after a message 1 ms · late fault onset after a message 999 ms
- Points
- latency limit: 2 s
- Steps
- For each onset, start NACK on every read, measure the time to the first
ERR SENSOR, then release the fault and wait for TEMP 25
- Expected
ERR SENSOR at most 2 s after the onset, for both onsets
- Pass criteria
- Every latency at most 2 s
Matrix: TMP-07 × PRF · Last result: PASSED 2 / 2
Code: benches/bench1_temp/tests/test_tmp07.py::test_tc_tmp07_prf_01
@tc("TC-TMP07-PRF-01")
@pytest.mark.regression
@requires(Fault.I2C_NACK)
@each("early fault onset after a message", "late fault onset after a message")
def test_tc_tmp07_prf_01(dut: TempMonitor, case: Case) -> None:
"""`ERR SENSOR` latency for one fault onset per test, then recovery."""
onset_after = case.input
message = stream_running(dut)
dut.wait_ms(message.t_ms + onset_after.ms() - dut.now_ms())
dut.inject_fault(Fault.I2C_NACK)
onset = dut.now_ms()
err = err_sensor(dut)
check_latency(
case, "latency limit", onset, err, f"the NACK onset {onset_after} after {message}"
)
dut.clear_faults()
readings_resume(dut, case)
TC-TMP07-FI-01
P1 · automated
NACK → ERR SENSOR within 2 s
- Class
- FI · fault injection and power loss
- Technique
- Simulator fault: NACK on every read
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · last good reading 25 °C
- Points
- latency limit: 2 s
- Steps
- Make the sensor NACK every read
- Expected
ERR SENSOR within 2 s (Q13 open: one ERR SENSOR or one per message both accepted)
- Pass criteria
ERR SENSOR within 2 s, no TEMP message after it
Matrix: TMP-07 × FI · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp07.py::test_tc_tmp07_fi_01
@tc("TC-TMP07-FI-01")
@pytest.mark.regression
@requires(Fault.I2C_NACK)
def test_tc_tmp07_fi_01(dut: TempMonitor, case: Case) -> None:
"""NACK on every read: `ERR SENSOR` in time, and no reading after it.
Questions: Q13 open (one `ERR SENSOR` or one per message both pass) and
Q19 assumed (the first failed read triggers it), stp.yaml.
"""
last_good_reading(dut, case)
dut.inject_fault(Fault.I2C_NACK)
onset = dut.now_ms()
err = err_sensor(dut)
check_latency(case, "latency limit", onset, err, "the NACK onset")
after = error_window(dut)
readings = of_kind(after, MessageKind.READING)
assert not readings, (
f"After {err} the sensor still NACKed and the device sent {describe(readings)}. "
f"Expected no `TEMP` message."
)
TC-TMP07-FI-02
P1 · automated
Stuck SDA → ERR SENSOR, no hang
- Class
- FI · fault injection and power loss
- Technique
- Simulator fault: SDA held low
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- latency limit: 2 s
- Steps
- Hold SDA low
- Release SDA
- Expected
ERR SENSOR within 2 s (Q13 open: one ERR SENSOR or one per message both accepted)TEMP 25 within 2 s of the release, so the firmware did not hang (Q8 assumed)
- Pass criteria
- Both steps
Matrix: TMP-07 × FI · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp07.py::test_tc_tmp07_fi_02
@tc("TC-TMP07-FI-02")
@pytest.mark.regression
@requires(Fault.STUCK_SDA)
def test_tc_tmp07_fi_02(dut: TempMonitor, case: Case) -> None:
"""SDA held low: `ERR SENSOR` in time, and readings again after the release, so no hang.
Questions: Q8 assumed (readings resume within 2 s), Q13 open and Q19
assumed, stp.yaml.
"""
stream_running(dut)
dut.inject_fault(Fault.STUCK_SDA)
onset = dut.now_ms()
err = err_sensor(dut)
check_latency(case, "latency limit", onset, err, "holding SDA low")
dut.clear_faults()
released = dut.now_ms()
back = readings_resume(dut, case)
check_latency(case, "latency limit", released, back, "the SDA release")
TC-TMP07-FI-03
P2 · automated
Single failed read → ERR SENSOR on that message
- Class
- FI · fault injection and power loss
- Technique
- Simulator fault: NACK on exactly one read
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · failed reads 1 NACK
- Steps
- Make the sensor NACK exactly one read, then answer again at 25 °C
- Expected
ERR SENSOR in place of the reading of the failed read, then TEMP 25 on the next message (Q19 assumed: the first failed read triggers it)
- Pass criteria
- Exactly one
ERR SENSOR, on the message of the failed read, with readings before and after it
Matrix: TMP-07 × FI · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp07.py::test_tc_tmp07_fi_03
@tc("TC-TMP07-FI-03")
@pytest.mark.regression
@requires(Fault.I2C_NACK)
def test_tc_tmp07_fi_03(dut: TempMonitor, case: Case) -> None:
"""Exactly one failed read: `ERR SENSOR` on that message only, readings before and after.
Questions: Q13 open and Q19 assumed (stp.yaml): the first failed read triggers it.
"""
before = stream_running(dut)
failed = int(case.value("failed reads"))
dut.inject_fault(Fault.I2C_NACK, count=failed)
onset = dut.now_ms()
got = [dut.next_message() for _ in range(failed + 1)]
want = reading_text(int(case.value("start temperature")))
expected = ["ERR SENSOR"] * failed + [want]
assert before.kind is MessageKind.READING and [m.text for m in got] == expected, (
f"Before the fault the device sent {before}. After {failed} failed read at {onset} ms "
f"it sent {describe(got)}. Expected {', '.join(f'`{t}`' for t in expected)}: "
f"`ERR SENSOR` in place of each failed read, then a reading."
)
errors = of_kind(since(dut, onset), MessageKind.ERR_SENSOR)
assert len(errors) == failed, (
f"The device sent {len(errors)} `ERR SENSOR` lines: {describe(errors)}. "
f"Expected exactly {failed}."
)
TC-TMP07-UPG-01
P1 · automated
Sensor returns: readings resume within 2 s
- Class
- UPG · upgrade and recovery
- Technique
- State transition ERROR → NORMAL
- Level
- regression
- Precondition
- Sensor NACKing every read,
ERR SENSOR received
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages
- Points
- resume limit: 2 s
- Steps
- Make the sensor answer again at 25 °C
- Expected
TEMP 25 within 2 s, no ERR SENSOR after it (Q8 assumed)
- Pass criteria
- Readings resume within 2 s without a restart
Matrix: TMP-07 × UPG · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp07.py::test_tc_tmp07_upg_01
@tc("TC-TMP07-UPG-01")
@pytest.mark.regression
@requires(Fault.I2C_NACK)
def test_tc_tmp07_upg_01(dut: TempMonitor, case: Case) -> None:
"""The sensor answers again: readings resume in time without a restart.
Questions: Q8 assumed (stp.yaml): readings resume within 2 s.
"""
stream_running(dut)
with precondition("sensor NACKing every read, `ERR SENSOR` received"):
dut.inject_fault(Fault.I2C_NACK)
err_sensor(dut)
dut.clear_faults()
dut.set_temperature(float(case.value("start temperature")))
answered = dut.now_ms()
back = readings_resume(dut, case)
check_latency(case, "resume limit", answered, back, "the sensor answering again")
after = dut.next_message()
assert after.kind is not MessageKind.ERR_SENSOR, (
f"After {back} the device sent {after}. Expected no `ERR SENSOR` once the sensor answers."
)
TC-TMP07-OBS-01
P3 · automated
Sensor fault names its cause on the UART
- Class
- OBS · observability
- Technique
- Error line on the UART
- Level
- regression
- Precondition
- UART stream running
- Test conditions
- supply 5.0 V · start temperature 25 °C · settle window 2 messages · last good reading 25 °C
- Steps
- Make the sensor NACK every read
- Expected
ERR SENSOR within 2 s and no ERR RANGE, so the line tells a sensor fault from a range error (Q17 assumed: no other diagnostics)
- Pass criteria
- The error line names the injected cause
Matrix: TMP-07 × OBS · Last result: PASSED 1 / 1
Code: benches/bench1_temp/tests/test_tmp07.py::test_tc_tmp07_obs_01
@tc("TC-TMP07-OBS-01")
@pytest.mark.regression
@requires(Fault.I2C_NACK)
def test_tc_tmp07_obs_01(dut: TempMonitor, case: Case) -> None:
"""A sensor fault names its cause: `ERR SENSOR`, not `ERR RANGE`.
Questions: Q17 assumed (stp.yaml): no diagnostics beyond the UART lines and the LED.
"""
last_good_reading(dut, case)
dut.inject_fault(Fault.I2C_NACK)
onset = dut.now_ms()
err = err_sensor(dut)
wrong = of_kind(since(dut, onset, err), MessageKind.ERR_RANGE)
assert not wrong, (
f"While the sensor NACKed, the device sent {describe(wrong)} before {err}. "
f"Expected `ERR SENSOR` and no `ERR RANGE`."
)